4-Wire Universal Cable/Harness Tester
Product model:LX-850
Product Features
Specifications
|
Items |
Code |
Test range |
|
Resistance |
R |
0.1Ω~10MΩ(accuracy1%) |
|
Capacitance |
C |
10pF~500uF |
|
Diode test |
D |
0.0V~7.0V |
|
Conductance |
COND |
0.01Ω~50Ω(accuracy1%) |
|
DC Insulation |
I.R |
0.1MΩ~1000MΩ |
|
AC High-voltage (drain current) |
lL |
0.1mA~10mA |
|
DC Hipot |
uA |
1uA ~ 1000uA |
|
Open /short |
0/S |
1KΩ~100KΩ |
|
Intermittent O/S |
INT.O/S |
2ms/64pin |
|
Intermittent Cond.
|
INT.COND |
0.01Ω~50Ω |
|
Instant on-resistance test |
COND |
0.05Ω~50Ω |
|
Quick instant short circuit |
Open |
1KΩ~50KΩ |
|
Advanced features |
Programmable continuous test Automatic directing Self-diagnosis Self-correction and zeroing |
Control panel |
System/fast/edit /feature/key groups |
|
|
Interface |
Printer port,Remote terminal control port RS-232 communication access port |
|||
|
Basic accuracy |
±1% |
Storage unit |
Built-in 512KB SRAM Built-in backup battery |
|
|
Test scanning mode |
Switchable auto/manual scanning |
|||
|
Measurement speed |
0.1Sec basic value
|
Power supply |
115/230Vac voltage input±10% 60/50Hz |
|
|
Measuring frequency and signal/voltage |
100~100KHz,1Vac |
|||
|
Low voltage measurement signal |
5Vdc,50mA Max Accuracy:±0.5% |
Accessories |
Automatic directing probeRemote terminal control cable (optional) RS: 232 signal cable (optional)Two-in-one 61Pin horn adapter Power line Manual (warranty card) |
|
|
High-voltage (drain current) test |
5~1000V dc(Model A) 5~1000Vdc and 100-700vac(Model B) 0.01~60Sec Delay time setting |
|||
|
High-voltage insulation test
|
5~1000V dc(Model A) 5V~1500Vac(Model B) Accuracy:±10% |
|||
|
Temperature and humidity
|
15~40 degrees Celsius Relative humidity: RH≤75% |
|||
|
Display/audio unit
|
640 × 480 TFT LCDcolor display 6-digit digital display Pass/Fail LED red indicator light/picture frame display/ sound
|
Dimensions (W×H×D)
|
425×190×350mm |
|
|
Weight |
About14Kg (Without accessories) |
|||
|
Wire specifications |
The maximum 1μF |
|||
|
Display measuring contacts
|
64 measuring contacts Optional 256/512 contacts High-pressure calibration positive and negative terminal output Automatic directing terminal
|
Electric Arc level |
0-9 can be choosed |
|
|
Ordering Information |
||||
|
LX-850A |
DC:5-1000V 64pins |
|||
|
LX-850B |
DC:5-1000V / AC:100-700V 64Pins |
|||
|
LX-850C |
DC:5-1500V / AC:100-1000V 64Pins |
|||
|
A2/B2/C2 |
128Pins |
|||
|
A3/B3/C3 |
256Pins |
|||